North County Detention Facility Reroof
County of Sonoma
Santa Rosa, CA
Services Provided:

Roof Designs and Repairs

The 22,500 square foot existing roof at the support services building at the North County Detention Facility, originally constructed circa 1985, was nearing the end of its expected life cycle and required replacement. In addition, the design of the rooftop mechanical system contributed to excessive and difficult maintenance requirements due to awkward duct placement, substandard mechanical equipment supports, and inadequate penetration detailing. Roof types include primarily low-slope built-up roof with asphalt shingles at the clerestory roof.

The reroofing design prepared by Interactive resources, in conjunction with Lefler Engineering, addressed the deficiencies as required to provide a durable, readily maintainable roof system. Features include improved thermal performance (due to the addition of 1.5 inches of rigid polyisocyanurate insulation), prefinished metal flashings, and penetration details and mechanical equipment platforms conforming to NRCA standards.